    APC ACRC301H Computerkühlsystemteil/-zubehör

    Hersteller: APC
    InRow RC, 300mm, Chilled Water, 208-230V, 50/60Hz - HT
    Artikelnummer: 270B200
    Herstellernummer: ACRC301H
    Verfügbarkeit: Nicht lagernd, bestellbar
    €15627,91 inkl. Steuer
    exklusive Versand
    i h
    Active Airflow Control Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment. Dew point monitoring Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature. Hot swappable fans Allows system to remain operational if a fan replacement is required. Leak detection Notifies user in the event of a water leak within the coiling unit. Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. Washable filters Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream. InRow Chilled Water CoolingFeatures & Benefits Availability Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy. Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment. Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. Serviceability Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors. Agility Modular design Modular design provides scalable solutions to add cooling as demand increases. Scaleable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures. Casters Provides flexibility to move the unit to wherever cooling is required. Manageability Real-Time Capacity Monitoring Real-time display of current and available cooling. Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display. Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system. Total Cost of Ownership Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures. Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.